DELL EMC D-VPX-DY-A-24 Real Exam Questions
The questions for D-VPX-DY-A-24 were last updated at Dec 22,2024.
- Exam Code: D-VPX-DY-A-24
- Exam Name: Dell VPLEX Deploy Achievement
- Certification Provider: DELL EMC
- Latest update: Dec 22,2024
What is the maximum cache of a single engine in a medium VPLEX VS2 cluster?
- A . 72 GB
- B . 36 GB
- C . 144 GB
- D . 78 GB
In addition to Active Directory, with what other directory service can VPLEX integrate for user authentication?
- A . LDAP
- B . NIS
- C . NDS
- D . PAM
What is the purpose of I/O module 2 in a the VPLEX VS2 hardware configuration?
- A . WAN-COM connectivity
- B . Front-end connectivity
- C . Back-end connectivity
- D . Local-COM connectivity
A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?
- A . The customer must connect the WAN-COM ports of the first engine only and disable the second engine from the VPLEX CLI.
- B . It is sufficient to connect the WAN-COM ports of either engine 1 or 2 because redundancy is provided by leveraging two separate SAN fabrics.
- C . The customer must provide additional SAN ports or acquire additional SAN ports to connect all WAN-COM ports of both VPLEX engines to the SAN.
- D . The customer must connect the WAN-COM ports of the first engine only and disable the second engine from the Unisphere for VPLEX GUI.
A customer is performing maintenance on their network that might affect their VPLEX Witness VM.
What can be done to ensure there are no adverse effects due to a Witness outage?
- A . Disable the cluster’s management server ipsec.
- B . Disable the VPLEX Witness.
- C . Shut down the VPLEX Witness VM.
- D . Shut down the cluster’s management server.
What is required of an ESX host for the Witness to be installed?
- A . Promiscuous mode set to Accept
- B . ESX host in Cluster 1 failure domain
- C . MAC address change set to Accept
- D . ESX host in Cluster 2 failure domain
During ndu pre-check, a partner found that metadata-backup is not working. In addition, metadatabackup volume components have been renamed.
How can the problem be resolved?
- A . Provision two new metadata volumes Re-run configuration metadata-backup
- B . Meta-volume destroy the actual metadata_backup Re-run configuration metadata-backup unclaimmetadata_backup
- C . unclaimmetadata_backup Re-run configuration metadata-backup
- D . Meta-volume destroy the actual metadata_backup schedule remove actual backup job unclaimmetadata_backup re-run configuration metadata-backup
You are zoning a dual-engine Local VPLEX cluster to a Symmetrix array to see LUNs 0010 and 0020 for metadata backups.
How many directors in the cluster must be zoned and masked to these LUNs?
- A . All of the directors
- B . Any two directors
- C . One from each engine
- D . Only one director
You are using VPLEX Unisphere to perform management functions in your environment. You are tasked with creating several volume migrations to a new storage array.
What tab should you use to perform this migration?
- A . Provision Storage
- B . Mobility Central
- C . System Status
- D . Performance Dashboard
What is the total number of engines for a small VPLEX Metro configuration?
- A . 1
- B . 8
- C . 4
- D . 2