DELL EMC D-PE-OE-23 Real Exam Questions
The questions for D-PE-OE-23 were last updated at Dec 20,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Dec 20,2024
A new server with default iDRAC network configurations is plugged into a segregated management network configured for 10.0.0.x/24. The technician cannot connect to the iDRAC.
How can the on-site technician configure the iDRAC for network access?
- A . Change iDRAC network settings from a workstation on the management network
- B . Perform an AC power cycle to reset the iDRAC
- C . Modify the iDRAC settings using the iDRAC Direct feature
- D . Configure a DHCP reservation for the iDRAC MAC address
One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.
Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU. After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.
The technician has taken the following actions:
– Reseated the PSU
– Checked the firmware version
– Checked the cable connections
The PSU continues to flash green then turn off.
What should the technician do?
- A . Check the Titanium PSU in another server to ensure it is not defective
- B . Wait for the PSU firmware to update
- C . Replace the 1100W PSU with a matching unit
- D . Change the redundancy from 1+1 to 2+0 and then enable the hot spare
A server administrator needs to access the iDRAC8 default interface. They are not using DHCP. They open a web browser and prepare to enter an IP address.
What IP address should they use?
- A . https://192.168.120.1
- B . https://192.168.0.120
- C . https://192.168.1.120
- D . https://10.195.2.120
A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8.
What login connection options are available on server using a secure port?
- A . DRM only
- B . RACADM CLI and DRM
- C . Web GUI and RACADM CLI
- D . Web GUI and SSH
What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?
- A . SupportAssist Enterprise
- B . iSM
- C . OpenManage Essentials
- D . iDRAC9
A server has the following configuration:
– 5x 1 TB drives configured in a RAID 5 array
– 1x 1 TB as a global hot spare
– Persistent Hot Spare Slot enabled
A user adds one additional 2 TB drive to the existing array using RAID migration.
How much disk space is available to the operating system?
- A . 5 TB
- B . 6 TB
- C . 7 TB
- D . 8 TB
What image does the iDRAC9 BIOS/UEFI Recovery feature use to flash a corrupt BIOS?
- A . Latest BIOS DUP from the online Dell catalog
- B . Last known good BIOS image
- C . Latest BIOS DUP that the system is aware of
- D . Dell DUP supplied by the system administrator
A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection.
What is the reason for the failure?
- A . Bluetooth is disabled on the mobile device.
- B . NFC is disabled on the mobile device.
- C . There is no iDRAC IP address configured.
- D . The mobile device is using iOS.
What is the minimum number of components, beside the system board, required to POST?
- A . 1 PSU, 1 DIMM, and 1 CPU only
- B . 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
- C . 1 PSU and 1 CPU only
- D . PSUs, CPUs, and DIMMs as configured in BIOS
What is the minimum number of components, beside the system board, required to POST?
- A . 1 PSU, 1 DIMM, and 1 CPU only
- B . 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
- C . 1 PSU and 1 CPU only
- D . PSUs, CPUs, and DIMMs as configured in BIOS