DELL EMC D-PE-OE-23 Real Exam Questions
The questions for D-PE-OE-23 were last updated at Dec 20,2024.
- Exam Code: D-PE-OE-23
- Exam Name: Dell Technologies PowerEdge Operate 2023
- Certification Provider: DELL EMC
- Latest update: Dec 20,2024
Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?
- A . 4x 3.5" drives
- B . 8x 3.5" drives
- C . 12x 2.5" drives
- D . 24x 2.5" drives
A technician receives a new server with five drives.
They need to configure the drives based on the following requirements received from the administrator:
– Drive 0 as a single disk with no RAID
– Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5
The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.
How should the technician configure the drives?
- A . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- B . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
- C . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- D . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.
What method can the technician use to quickly switch to DHCP?
- A . Reboot each server to enable DHCP default settings
- B . Boot into CTRL+S and change iDRAC settings to DHCP
- C . Use the LCD panel to input a new IP address
- D . Log in to the iDRAC and enable DHCP
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?
- A . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server stays operational - B . Remaining fans stay at the recommended RPM
iDRAC slows down the speed of the CPUs to avoid a temperature increase
LCD changes to blue but an alert would have been sent out - C . Remaining fans increase RPM to compensate for the removed fans
LCD changes to amber and displays an error message
Server performs a controlled shutdown - D . Remaining fans increase RPM to compensate for the removed fans
LCD changes to blue and displays an error description
Server performs a controlled shutdown
Case Study 1
A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated.
The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user’s home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas.
The company has a total of 60 AD forests:
– 1 main domain
– 55 domains have one-way trust relationships with the main domain
– An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.
Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet.
The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.
How many tenant Access zones will be required?
- A . 1
- B . 55
- C . 59
- D . 60
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
- A . The LCC can be rolled back; the iDRAC cannot be rolled back
- B . The iDRAC cannot be rolled back and the LCC cannot be rolled back
- C . The iDRAC can be rolled back; the LCC cannot be rolled back
- D . Both the iDRAC and the LCC can be rolled back
A technician must update the firmware on a savor, but has no network connectivity.
What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?
- A . OpenManage Server administrator DVD
- B . ftp dell.com
- C . NFS share
- D . USB key with Dell Update Package
What is the result when iDRAC is in Lockdown Mode?
- A . iDRAC is only accessible to administrators.
- B . The virtual console is not accessible.
- C . Local iDRAC users have read-only access.
- D . Lifecycle Controller is inaccessible.
An error occurs during data transmission between the CPU and DIMM.
Which feature in a Dell PowerEdge 16G server is responsible for fixing correctable memory errors?
- A . Memory Retraining
- B . Persistent Memory
- C . Post Package Repair
- D . Memory Health Check
Which two tools provide a user interface to manage the Boot Optimized Storage Solution (BOSS) cards? (Select 2)
- A . OpenManage Mobile (OMM)
- B . Intelligent Platform Management Interface Tool (IPMITool)
- C . Integrated Dell Remote Access Controller (iDRAC)
- D . OpenManage Server Administrator (OMSA)
- E . Remote Access Controller Admin (RACADM)