VMware 5V0-21.21 Real Exam Questions
The questions for 5V0-21.21 were last updated at Nov 19,2024.
- Exam Code: 5V0-21.21
- Exam Name: VMware HCI Master Specialist
- Certification Provider: VMware
- Latest update: Nov 19,2024
An architect is designing for a production vSAN cluster, and the customer introduced these requirements related to File Services: A minimum of 12 files shares. 30TB NFS capacity to mount workload VMs.
What should be the architect’s recommendations?
- A . Point out the risks regarding putting the hosts in maintenance mode in terms of FSVM.
- B . Confirm on all of the requirements and move forward with the physical design.
- C . Raise concerns regarding support when running VMs on an NFS share as risk.
- D . Highlight the required number of nodes required for the vSAN cluster as a constraint.
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)
- A . Forged Transmits
- B . Promiscuous Mode
- C . DVFiltering
- D . Jumbo Frames
- E . MacLearning
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).
Which step should be taken to resolve this issue?
- A . Configure vmk0 with IP address on the same range as that of vmk1.
- B . Tag the vmk0 for vSAN traffic.
- C . Configure vmk1 with IP address on the different network than that of vmk0.
- D . Tag the vmk1 for Witness traffic.
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer’s requirements?
- A . Five nodes All-Flash vSAN cluster
- B . Six nodes All-Flash vSAN cluster
- C . Six nodes Hybrid vSAN cluster
- D . Five nodes Hybrid vSAN cluster
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?
- A . The cluster will be partitioned and the vSAN host will need to be rejoined.
- B . A rebuild of the affected objects will occur.
- C . All objects will remain accessible.
- D . All objects on the affected host will be lost.
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system.
The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?
- A . A 16GB single-level cell (SLC) SATADOM device must be used.
- B . A 4GB USB or SD device must be used.
- C . A 16GB multiple-level cell (MLC) SATADOM device must be used.
- D . ESXi Hosts must boot from a PMEM device.